Fire glossary
Glossary search
Click a letter to view all entries that begin with that letter.
A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
29 entries in the Fire glossary beginning with "D"
Dalmatian
Firehouse dog.
Dead lay
A load of hose on a pumper, but not connected to a pump outlet. Often used for larger supply lines.
Dead Man Zone
Unburnt areas around edges of brush fire.
Deck gun
A master stream device mounted to top deck of pumper.
Deflagration
An explosion with a propagation front traveling at subsonic speeds, as compared to supersonic detonation.
Deluge gun
A master stream device that can be positioned on the ground based on the need of the incident commander.
Deluge system
Type of sprinkler system in which sprinkler heads do not have individual valves, and the water (or other extinguishing agent) is disbursed from all sprinkler heads simultaneously when a central (or zoned) valve is triggered by a sensor (or manually). Typically reserved for industrial areas where rapid fire spread must be prevented at the cost of damaging non-burning materials.
Demob
Demobilization, or a crew being removed from working a fire.
Denver Door opener
Heavy pry bars connected with a hinge, one with an adjustable foot, used for prying open doors.
Denver tool (also called TNT tool)
A combination axe, sledgehammer, pry tool, ram, and D-handle pull tool used to gain forcible entry to buildings, automobiles, etc. during emergency situations.
Detection system
See Alarm system.
Detergent foam
See Aqueous Film Forming Foam.
Direct Attack
Any treatment applied directly to burning fuel such as wetting, smothering, or chemically quenching the fire or by physically separating the burning from unburned fuel.
Direct attack
Putting the wet stuff on the red stuff." A form of fire attack in which hoses are advanced to the fire inside a structure and hose streams directed at the burning materials.
Discharge flow
The amount of water flowing from a fire hydrant when it is opened; compare to static flow and residual flow.
Dispatch
Refers to person or place designated for handling a call for help by alerting the specific resources necessary.
Distributor pipe
Portion of fire hydrant or sprinkler system connecting main loops to smaller loops where outlets are located.
Double female
Firehose adapter for connecting two male" couplings together; may also adapt different sizes on either side.
Double male
Hose coupling adapter with two male-threaded connectors back-to-back; used for connecting two female couplings together.
Dozer line
Fireline constructed by the front blade of a bulldozer or any tracked vehicle with a front mounted blade used for exposing mineral soil. Also catline.
Draft
The process of pumping water from a static source below the pump.
Drafting
Using a suction pump to lift water from below the pump, using a semi-rigid suction hose, typically to fill a portable reservoir that has other suction pumps (to relay) or siphon hoses running downhill to their nozzles.
Drills
Training during which an emergency is simulated and the trainees go through the steps of responding as if it were a real emergency.
Drip torch
Hand-carried fire-starting device filled with flammable liquid that is poured across a flaming wick, dropping flaming liquid onto the fuels to be burned.
Dry chemical
A fire extinguishing agent. It works by breaking the chemical chain reaction in the fire tetrahedron".
Dry hydrant
A fire hydrant with a valve located at the bottom of the barrel, near the water main. The barrel of the hydrant remains dry until used. The prevents the hydrant from freezing in sub-zero temperatures. A dry hydrant is also an unpressurized pipe that can be used to draft water from a pond or lake.
Dry powders
Fire extinguishing agents for use on flammable metals. Each agent is typically designed for use on either a single metal or very similar metals.
Dry sprinkler
A sprinkler system having pressurized air (rather than water) in the distribution pipes until a heat-activated sprinkler head opens and releases the pressure, which opens a water valve (and possibly an accelerator valve) to flow water to the open head; used where the protected premises are not heated during freezing temperatures or where pressurized water in overhead sprinkler pipes could create another hazard.
Duff
Layer of decaying forest litter consisting of organics such as needles, leaves, plant and tree materials covering the mineral soil. Duff can smolder for days after a fire. Extinguishing smoldering duff is key to successful mopup operations.
29 entries in the Fire glossary beginning with "D"
Tuesday, November 15th, 2022
picture
Tonight the crews went to Evergreen to go over TICs and had meters Laurel Gardens was also at the training night.
Keating Fire Company does not ask for donations over the phone.We send out donations request’s by mail and will never ask any of the Ross Township residence for any type of money over the phone....
Tuesday, September 6th, 2022
https://www.penndot.pa.gov/TravelInPA/Pages/Yellow-Dot.aspx Please click on the link and register today.
November 2022
S
M
T
W
T
F
S
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
2022 total
Incidents
153
1. Line Officers

Chief: John Clifford

Asst. Chief: John McDermitt

Captain: Mike Zeitler

Lieutenant: Ron Koss

Lieutenant: Scott Elliot

Lieutenant: Jared  Nock

Safety Officer: Randy Schmucker

2. Admin Officers

President:     William Marciniak

VP:                 John Reitlinger

Recording Sec: John Reubi

Financial Sec:   Richard Schnarrenberger

Treasurer:          Robert  Reubi

Director:             Neal Beley

Director:             Tom Conroy

Director:            Scott Elliot

Director:            Wayne King

Director:            Brian Zeitler

Director:            Greg Zeitler

Director:            Mike Zeitler

Youngstown Fire Department-Station 39
CCAC Public Safety Institute
Ross Township Fire Police-Station 254

© 2022 Keating Fire Company